Great Aquariums Start Here
1-800-566-3474
    Free Shipping On $175+
  • FREE Shipping On $175+
  • 14-Day Low Price Guarantee
  • 14-Day Low Price Guarantee
  • Same Day Shipping
  • Same Day Shipping
FREE Shipping on Orders Over $175
FREE Shipping on
Orders Over $175
Standard ground shipping (1-7 business days) starts at a low $5.99 and most orders over $175 ship FREE. Learn More
14-Day Low Price Guarantee
If you find a product we sell for a lower price at another online store, we will match their price—today and up to 14 days after you've purchased the item! Learn More
Same Day Shipping
Same Day Shipping
We promise to ship your order as fast as humanly possible. In fact, 99% of orders placed before 6 pm EST ship the same day! Learn More

American Marine Pinpoint Salinity Monitor Information

American Marine is proud to introduce PINPOINT ™ Salinity Monitor, the only truly accurate and affordable Salinity measurement system. A 9-volt battery should be used for intermittent or field use while a PINPOINT AC Adapter Kit can also be installed. Battery replacement is visually indicated on the display as "LOBAT".

NOTE: The Salinity Monitor unit is NOT waterproof and must be operated on a dry surface. Liquid contact on the printed circuit board will cause corrosion and void warranty.

Set-up:

Unwrap the protective plastic packaging from the Salinity Monitor Unit. Remove the battery cover on the back of the monitor and install a 9-volt battery or the PINPOINT AC Adapter Kit. Activate the unit by setting the power switch to the ON position. Use the pop-up stand on back and place meter on any flat, dry surface.

Your PINPOINT Salinity Monitor™ is now ready for calibration.
PINPOINT ORP Controller
Reef Aquarium
Calibration ProcedurePINPOINT Salinity Monitor Diagram

Note: The meter should be calibrated immediately before use. The calibration should be checked occasionally to verify your readings. The precise measurement of Salt by electronic conductive means has long been considered to be the most accurate method, especially when compared to Specific Gravity / Density (hydrometers) and refractometers.

Marine environments should use the calibration fluid labeled 53.0mS. Empty the 53.0mS into a small, clean cup and swirl the probe in the fluid making sure that no air bubbles have accumulated under the probe. Wait 2-3 minutes to allow for the temperature thermistor inside the probe tip to properly compensate for any temperature differences between the fluid and the probe. Using a miniature screwdriver, turn screw #3 (see diagram) until the display matches the 53.0mS fluid (±0.5). The calibration adjustment screw #3 is located inside the battery compartment most toward the center of the meter. Note that the blue chart will convert the display readings to either ppt (” Salt) and/or SG (Specific Gravity).

Koi and Freshwater Systems benefit greatly from only a small level of added salt. Typically, a .3% level is considered optimum. These low levels can only be accurately measured with a PINPOINT Salinity Monitor. Hydrometers and refractometers are generally impossible to use at these low salt levels. The PINPOINT Salinity Monitor should first be calibrated with a .3% salt fluid. Prepare this fluid by mixing 11.4 grams of pure uniodized table salt (Kosher Salt) with 3,785mL (1 gallon) of distilled or deionized water. Submerge the probe into this .3% calibration fluid and calibrate the PINPOINT Salinity Monitor to display 5.5mS by adjusting screw #3. Your PINPOINT Salinity Monitor is now calibrated to read the low salt levels of a Koi pond, etc. Be sure to take into account the existing salt level in a pond before adding any additional salt.

Salinity is a complex subject and one must be sure of the target specific gravity or ppt Salt has been properly selected in advance. The PINPOINT Salinity Monitor is automatically temperature compensated therefore the displayed values are already compensated and corrected.

NOTE: Do not adjust screw #4 since this is used to set frequency and requires specialized equipment for adjustment. Screw #4 has been set at the factory and does not require further adjustment. A small amount of glue has been placed on screw #4 to prevent accidental adjustment.

Important Points to Remember:
  • The PINPOINT Salinity Meter is NOT waterproof and must be operated on a dry surface. Any liquid contact on the printed circuit board will cause corrosion and void warranty.
  • It is important to "swirl" the probe so as to eliminate any air bubbles that may accumulate under the probe before taking a measurement.
  • The probe is epoxy sealed and can be totally submerged.
  • The electrode should be cleaned every few months with a very weak solution of water (16 oz.) and dishwashing detergent (1/2 teaspoon). Rinse the electrode well with fresh water.
  • The PINPOINT Salinity Monitor is automatically compensated throughout the temperature range 32°F to 122°F (0° to 50°C).
  • Calibrate the monitor with the appropriate fluid before use.
  • Check the calibration occasionally. Calibration fluid can be re-used if uncontaminated by other fluids and kept in a tightly capped container.
Reference Chart Sources:
  1. Zerbe and Taylor (1953)
  2. Cox R.A., The Physical Properties of Seawater, Chemical Oceanography
    Vol. 1, Riley, J.P. and Skirrow, G. Eds., Academic Press, London, 1965.
Warranty:

Pinpoint Salinity Monitor by American Marine Inc. is warranted to be free of defects in material and workmanship for a period of 2 years from date of sale. Positive proof of purchase is required for warranty claim.

Removal or alteration of the serial number will void warranty.

American Marine Inc. will not be liable for any costs of removal, installation, transportation charges, or any other charges, which may result in connection with a warranty claim.

American Marine Inc. will not be liable for any damage or wear to products or livestock caused by abnormal operating conditions, water damage, abuse, misuse, unauthorized alternation or repair or if the product was not installed in accordance with the printed operating instructions.

Any defective product to be returned must be sent freight prepaid with appropriate documentation supporting the warranty claim. Replacement or repair will be at the discretion of American Marine Inc. Typical turnaround time within 48 hours. Overnight delivery available.

This item is temporarily unavailable but will be back in stock soon.

Item #
Price:
Click the Add To Cart button below if you'd like to reserve this item today. Any other items included in your order will be immediately processed and shipped. We will ship this item separately as soon as it arrives. We will not charge you for this item until it ships and you will incur no additional shipping charges.

Enter your email address in the field below and click the Notify Me button if you'd like us to send you an email when this item becomes available. Although you will be immediately notified when we have stock on hand, we will not reserve any units for you; you must return to our website and place an order.

Your Email:
Just enter your email address below and we'll let you know when the product you are looking for becomes available!

Item Code:
Price:
Your Email:
Email Specials
Subscribe to our newsletter feed.
Newsletter Tips & Tricks! New Products!
Discounts & Promos!
Testimonials
Aug 18, 2014
"I like how easy it is to do business with Marine Depot. I also love the competitive prices on products."
Joshua

Aug 15, 2014
"The best online place to shop for all aquarium supplies. The best packing ever: I've ordered lights, nothing has ever broken."
Corals&Clowns

Aug 13, 2014
"Great place to buy reef aquarium products."
Gabe

Marine Depot Newsletter Signup
Aquariums, News & Culture
Join 100,000+ readers who receive weekly tips, videos, deals and giveaways.